Product Overview
Sylvania High Efficiency QHE2x32T8/UNV-ISN-SC-1 Normal BF 120/277V 2-Lamp Electronic T8 Ballast Used In Refrigerated cases, Walk-in coolers,Etc And Will Operates The Following
- (2) FO17 24in Fluorescent Lamp
- (2) FO25 36in Fluorescent Lamp
- (2) FO32/25W 48in Energy Saving F32T8 25W Lamps
- (2) FO32/28W 48in Energy Saving F32T8 28W Lamps
- (2) FO30/SS (48in Energy Saving F32T8 30W Advantage Lamps)
- (2) F32T8 (48in FO32/ECO 32W Standard Lamps)
- (2) FBO16,FBO24, FBO29/SS, FBO30/SS, FBO31, FBO32 U-Bend Lamps
- (1) FO40 60in Fluorescent T8 Lamp
Additional Information:
Sylvania Quicktronic High Efficiency T8 Type CC ballasts will operate various 1-4 Lamp combinations ideally suited for applications that could expose lamp and sockets to vibration and potential movement. Additional Benefits Lamp Striation Control, (LSC) General lighting applications where energy saving T8 lamps may striate,particularly for the F25 energy saving T8 lamps
- Normal Ballast Factor 0.87
- 70C Max Case Temperature
- Lamp Striation Control
- UL Listed Class P, Type 1 Outdoor
- Ground ballast case
- Lampholder must be shorted per diagram
- High Efficiency Systems over 90% efficient
- UL Type CC Rated (Commercial Cabinet)
- -20ºF (-29ºC) min. starting temp. for Octron T8 lamps
- QHE ballasts also meets the most demanding utility rebate standards
- Install in accordance with National Electric Codes
- Complies with FCC 47 CFR Part 18, Non-Consumer
- ANSI 62.41 Cat. A Transient Protection
- Class A Sound Rating.
- Input Frequency: 50/60Hz.
- Complies with UL935 requirements for "Type CC" rating
- Minimum starting temperature: 60 F / 16 C with SS lamps
- Minimum starting temperature: -20 F / -29 C
- CSA certified.
- ANSI C82.11 where applicable.
- NO PCB (Polychlorinated Biphenyl)
- Remote mounting up to 20 feet Lamp Striation Control (LSC) may minimize
- F60ºF (16ºC) min. starting temp. for Octron Supersaver 25W,28W,30W lamps
- Or eliminate lamp striations which can occur in T8 energy savings lamps.
- Small Can Enclosure Design (Dim:9.47”L x 1.69”W x 1.18”H)
- Minimum starting temperature: -20 F / -29 C
- Complies with FCC 47 CFR Part 18, Non-Consumer
- Normal Ballast Factor < 10% THD
- Dual Voltage 120-277V 50/60Hz
- Circuit Type Parallel
- Meet NEMA Premium Electronic M Ballast Program Requirements and qualify for utility incentives
- Deliver 30-60% energy savings when D compared to F34T12 magnetically ballasted systems
- Offer up to 6% (2-5 Watt) energy O savings over standard electronic ballasts
- Bi-level QUICKSTEP and POWERSENSE Dimming models
- Excellent for The Most Stringent energy codes and