Sylvania 21720 FO32/865/XP/ECO

(No reviews yet) Write a Review
$8.93
SKU:
SFB21720
UPC:
46135217203
Condition:
New
Availability:
Shipping:
$16.71 (Fixed Shipping Cost)

Product Overview

sylvania-logo.png

Sylvania 21659 32W Octron 800XP 6500K Fluorescent 48in High Lumen T8 Extended Performance  Ecologic Lamp

  • Length:48
  • Diameter:1
  • Base: Medium Bipin
  • Bulb:T8
  • CRI:81
  • Initial Lumens: 2925
  • Rated Life:40000

   Additional Information

Sylvania OCTRON 800-XPS Ecologic Lamps are the highest lumen 4-foot T8 lamps in the Octron product offering. They feature up to 10% higher initial output, better lumen maintenance, higher CRI and up to 40% longer life than 700 Series T8 lamps. COLOGIC fluorescent lamps provide up to 42% longer life, higher initial and maintained lumens, improved color rendition and longer re-lamp periods compared to 700 Series T8 lamps. For maximum energy savings, operate OCTRON 800 XP ECOLOGIC lamps on QUICKTRONIC high efficiency instant start ballasts. For longer life and optimal performance on occupancy sensors, pair with QUICKTRONIC PROStart® programmed rapid start ballasts.

Mean lumens are measured at 40% of average rated lamp life. Minimum starting temperature is a function of the ballast; consult the ballast manufacturer. Approximate initial lumens after 100 hours operation. OCTRON lamps should be operated only with magnetic rapid start ballasts designed to operate 265 mA, T8 lamps or high frequency (electronic) ballasts that are either instant start, or rapid start, or programmed rapid start specifically designed to operate T8 lamps. OCTRON lamps may be operated on instant start ballasts with ballast factors ranging from a minimum of 0.71 to a maximum of 1.20 at the nominal ballast input voltage. When OCTRON lamps are operated in the instant start mode, the two wires or two contacts of each socket should be connected to each other. They should then be connected to the appropriate ballast lead wire using National Electric Code techniques. The life ratings of fluorescent lamps are based on 3 hour operating cycles under specified conditions and with ballast meeting ANSI specifications. If operating cycle is increased, there will be a corresponding increase in the average hours life. SUPERSAVER® lamps are recommended to be used on F32T8 ballasts with minimum open circuit voltage of 550V RMS at the lamp. Not recommended to be used: (1) in remotely ballasted fixtures with lamp open circuit voltages below 550V, (2) with Rapid Start ballasts unless the lamp open circuit voltage is greater than 570V, (3) in air handling fixtures, (4) on low power factor ballasts or (5) inverter operated emergency lighting systems unless the equipment is specifically listed for particular lamps. Any of the above situations could result in lamp starting and stabilization problems, or system compatibility issues. If an operating lamp is exposed to drafts or the ambient temperature falls below 60ºF (70ºF for 25W), striation (a rhythmic pulsing pattern of light running down the tube) and/or reduction in lamp brightness may occur. While visually disconcerting, neither behavior is damaging to the lamp and removing the cause (draft or temperature) will return the lamp to normal operation.

Reviews

(No reviews yet) Write a Review